Backloading for Trusscore Wall&CeilingBoard

Download PDF Copy (ENG)

Trusscore® Wall&CeilingBoard™ is designed for industry-leading strength and durability, making it an ideal solution for ceiling applications. Trusscore Wall&CeilingBoard is engineered to support the installation of insulation behind panels, often referred to as backloading, for common insulation R-values including insulation types found in most residential applications. 

When used for ceiling applications at joist spans of 16”, insulation R-values up to R80 can be safely installed above Trusscore Wall&CeilingBoard with no visible deflection in the panels. 

For joist spans of 24” and 48”, the following table can be used as a guideline to determine expected panel deflection based on different insulation types at various insulation R-values. The values shown below are based on dry environment conditions and may vary if exposed to moisture.

Fiberglass Batt Fiberglass Blown-In Cellulose Stone Wool
Span Span Span Span
R 24" 48" 24" 48" 24" 48" 24" 48"
10 0.037" 0.075" 0.036" 0.074" 0.044" 0.102" 0.048" 0.117"
20 0.042" 0.093" 0.043" 0.096" 0.057" 0.148" 0.064" 0.175"
30 0.046" 0.111" 0.049" 0.118" 0.069" 0.193" 0.080" 0.234"
40 0.051" 0.129" 0.055" 0.140" 0.081" 0.238" 0.096" 0.292"
50 0.056" 0.147" 0.061" 0.162" 0.093" 0.283" 0.112" 0.351"
60 0.061" 0.165" 0.067" 0.184" 0.106" 0.328" 0.128" 0.409"
70 0.066" 0.183" 0.073" 0.206" 0.118" 0.373" 0.144" 0.468"
80 0.071" 0.200" 0.079" 0.228" 0.130" 0.418" 0.160" 0.526"

 We do not recommend exceeding these insulation R-values when using Trusscore Wall&CeilingBoard. Consult the Trusscore Wall&CeilingBoard Installation Guide to achieve the best results.